HKTS 11 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 14

Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online

 
Page 8 of 48 
Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
8.6 
Class II equipment and Class II constructions within Class I equipment 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
 P 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Mains transformer 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged 
with 2 capacitors in series complying with 
14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged 
with a single capacitor complying with 14.2.1 b) 
 N/A 
 
Basic insulation bridged by components 
complying with 14.3.4.3 
 N/A 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
This clause is not considered 
N/A 
 
Reinforced or double insulation between 
circuits operating at voltages between 35 V and 
71 V (peak) a.c. or between 60 V and 120 V 
d.c. and hazardous live parts at higher voltage 
 N/A 
 
Separation by Class II isolating transformer 
 
N/A 
 
Separation by Class I transformer 
 
N/A 
 
Separation by earthed conductive part 
 
N/A 
8.8 
Double Insulation: the Basic or Supplementary 
insulation > 0,4 mm (mm)  ................................. :
Prim. wires 
 
Reinforced insulation > 0,4 mm (mm)  .............. : Transformer bobbins 
 
Thin sheet insulation used inside the enclosure.  
N/A 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 dielectric 
 N/A 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 dielectric 
 N/A 
 Reinforced 
insulation, 
two layers each of which 
meet 10.3 dielectric 
 
N/A 
 
Reinforced insulation, three layers any two 
which meet 10.3 dielectric 
 
N/A 
8.9 
Primary Wiring: Adequate insulation between 
internal hazardous live conductors and 
accessible parts 
Applies to Class I equipment 
N/A 
 
Secondary Wiring: Adequate insulation 
between internal hazardous live parts and 
conductors connected to accessible parts 
 N/A 
Page of 62