Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online
Page 14 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
14 COMPONENTS
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved ......................... :
N/A
14.2
Capacitors and RC units
Capacitors separately approved
N/A
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ................................................................ :
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ................................................................ :
P
14.2.3
Capacitors operating at mains frequency but
not connected to the mains: tests for X2 .......... :
not connected to the mains: tests for X2 .......... :
N/A
14.2.5
a)
a)
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B
or better ................................................................
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B
or better ................................................................
N/A
b)
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source
than table 5 permits: compliance with
IEC 60 384-1, 4.38 category B or better ........... :
mounted closer to a potential ignition source
than table 5 permits: compliance with
IEC 60 384-1, 4.38 category B or better ........... :
N/A
Shielded by a barrier per Table 21 .................... :
N/A
14.3
Inductors and windings
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type ......................... :
manufacturer's name and type ......................... :
Transtec TT0900305570-E alt.
Gloria TD-230-0250K alt.
HuiRan 150-r4055904-e
Gloria TD-230-0250K alt.
HuiRan 150-r4055904-e
P
Transformers and inductors separately
approved ............................................................ :
approved ............................................................ :
No
N/A
14.3.2
General
14.3.3 Constructional
requirements
(complete
appended tables or include manufacturers
constructional insulation descriptions)
constructional insulation descriptions)
P
14.3.3.1
Clearances and creepage distances comply
with clause 13
with clause 13
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
P
Click on the first or last page to see other HKTS 11 (serv.man13) service manuals if exist.