Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online
Page 16 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
14.5.2.2
Correct marking of fuse-links adjacent to holder . T1.6AL 250V
P
14.5.2.3
Not possible to connect fuses in parallel .......... : No
P
14.5.2.4
Not possible to touch hazardous live parts
when replacing fuse-links without the use of a
tool ..................................................................... :
when replacing fuse-links without the use of a
tool ..................................................................... :
Tools are required
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking
capacity and their position is correctly marked
capacity and their position is correctly marked
N/A
14.6
Switches
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
V-0 compliance with annex G, G.1.1
and
Peak inrush rating of switch
Measured/calculated inrush............................... :
Mains switch, (MOMS)
Measured current consumption:
0.21A. Calculated peak surge
current: 23A (measured:128A)
0.21A. Calculated peak surge
current: 23A (measured:128A)
P
14.6.1 b)
Tested in the apparatus:
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling = 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has
making/breaking action independent of speed
of actuation
61058-1 subclause 13.1 and has
making/breaking action independent of speed
of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate
dielectric strength
dielectric strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N/A
Socket outlet current marking correct
N/A