Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online
Page 9 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
8.10 Class
II
Wiring:
(1) Primary: Double insulation between
conductors connected to the mains and
accessible parts.
conductors connected to the mains and
accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and
the mains
conductors connected to accessible parts and
the mains
Live wires from transformer are double
insulated.
insulated.
No sec wire can come into contact
with live bare parts.
with live bare parts.
P
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No risk of any wire becoming
detached
detached
N/A
Vibration test carried out ................................... : No, no need. See above
N/A
8.12
Adequate cross-sectional area of internal wiring
to mains socket-outlets
to mains socket-outlets
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
P
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
(2N force)
wiring due to hot parts or sharp edges
(2N force)
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional
interleaved insulation
interleaved insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1 Disconnect
device
Mains
plug
P
All-pole switch or circuit breaker with >3mm
contact separation
contact separation
N/A
8.19.2
Mains switch ON indication
Power I
P
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
Across L-N (EMI filter)
P