HKTS 11 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 15

Read Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate online

 
Page 9 of 48 
Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
8.10 Class 
II 
Wiring: 
(1) Primary: Double insulation between 
conductors connected to the mains and 
accessible parts. 
(2) Secondary: Double insulation between 
conductors connected to accessible parts and 
the mains 
Live wires from transformer are double 
insulated.  
 
 
No sec wire can come into contact 
with live bare parts. 
8.11 
Detaching of wires 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
No risk of any wire becoming 
detached 
N/A 
 
Vibration test carried out  ................................... : No, no need. See above 
N/A 
8.12 
Adequate cross-sectional area of internal wiring 
to mains socket-outlets 
 N/A 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 P 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
 P 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges            
(2N force) 
 P 
8.16 
Only special supply equipment can be used 
 
N/A 
8.17 
Insulated winding wire without additional 
interleaved insulation 
 N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
 
 
8.19.1 Disconnect 
device 
Mains 
plug 
 
All-pole switch or circuit breaker with >3mm 
contact separation 
 N/A 
8.19.2 
Mains switch ON indication 
Power  I 
8.20 
Switch not fitted in the mains cord 
 
8.21 
Bridging components comply with clause 14 
Across L-N (EMI filter) 
 
Page of 62