Page 22 of 66 
 
Report No.: HK-R04173361 
 
IEC 60065 / EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN60065D 
Intertek Testing Services Hong Kong Ltd.
 
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 
Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 
 
Switch controlling > 0.2A with open contact voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and 
V-0 in annex G, G.1.1 
 N 
 
Switch controlling < 0.2A with open contact voltage 
> 35 V (peak)/24 V dc complying with 14.6.4 and 
V-0 in annex G, G.1.1 
 N 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking 
 action independent of speed of actuation 
 N 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d), l) and m) not 
attaining excessive temperatures in use 
 N 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
 N 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1 
No mains socket outlet 
 
Socket outlet current marking correct 
 
14.7 
Safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
No such device 
14.8 
Voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
No such device 
14.9 
Motors 
14.9.1 
Endurance test on motors 
No motors used 
 Motor 
start 
test 
 
 
Dielectric strength test 
 
14.9.2 
Not adversely affected by oil or grease etc. 
 
14.9.3 
Protection against moving parts 
 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
 
14.10 
Batteries 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 P 
Page of 98
Display