Read Harman Kardon HK 970 (serv.man13) EMC - CB Certificate online
Page 21 of 66
Report No.: HK-R04173361
IEC 60065 / EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN60065D
Intertek Testing Services Hong Kong Ltd.
2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com
14.5.1.2
a) Thermal links separately approved
Thermal fuses complied with
IEC 60691 were used
IEC 60691 were used
P
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
No such device
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Mains fuse-link (FUSE) and
secondary fuse-links (F1, F2 &
F601)
secondary fuse-links (F1, F2 &
F601)
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : Marking for fuse-link holder
(FUSE): T4AL/250V
Marking for secondary fuse-
links:
links:
− F1: T4AL250V
− F2: T4AL250V
− F601: T1AL/250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... : P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ........ :
replacing fuse-links without the use of a tool ........ :
Tools are required
P
14.5.3
PTC thermistors comply with IEC 60730-1
No such device
N
PTC devices (15 W) category V-1 or better
N
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
Marking for secondary micro
fuses:
fuses:
F602:
1A/125V
F603:
1A/125V
P
14.6
Switches
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
Relay (L901) was complied
with IEC61058-1 and G.1.1
with IEC61058-1 and G.1.1
P
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
N
Click on the first or last page to see other HK 970 (serv.man13) service manuals if exist.