Read Harman Kardon BDS 275 EMC - CB Certificate online
Page 50 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
NO Norway
NO
15.1.1
Mains socket-outlets mounted on CLASS II apparatus shall comply with the
specifications given in CEE Publ. 7 as fas as applicable, with the following amendments:
specifications given in CEE Publ. 7 as fas as applicable, with the following amendments:
§ 8 Dimensions
a 2,5 A 250 V two-pole socket-outlets for electronic apparatus shall comply with the
enclosed Standard Sheet I.
enclosed Standard Sheet I.
§ 24 Mechanical strength
a 2,5 A, 250 V socket-outlets for CLASS II electronic apparatus are tested as specified
in 12.1.3 of EN 60065.
in 12.1.3 of EN 60065.
Also the protecting rim shall be tested.
Justification:
Act of 24 May 1929 relating to supervision of electrical installation (TEA 1929/FEL 1998).
N/A
J2
After Table J.1 the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral is not
provided.
distribution system where the neutral is not
provided.
P