Read Harman Kardon AVR 460 (serv.man2) EMC - CB Certificate online
- Page 18 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
Component meets category V-1 of IEC 60707
…......:
…......:
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission ………………………………:
part of the submission ………………………………:
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission ………………………………:
part of the submission ………………………………:
N/A
14.5 Protective
devices
P
Protective devices used within their ratings ………:
Thermal link and fuses
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened ………………………......:
requirement of clause 13 for the voltage across the
device when opened ………………………......:
Certified protective devices
applied. See appended table,
list of critical components.
applied. See appended table,
list of critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved …………:
No thermal cut-outs
N/A
b) Thermal cut-outs tested as part of the submission:
N/A
14.5.1.2
a) Thermal links separately approved …………..:
Thermal link in main transf.,
separately approved compo.
See appended table,
list of critical components
separately approved compo.
See appended table,
list of critical components
P
b) Thermal links tested as part of the submission ….:
N/A
14.5.1.3
Thermal devices re-settable by soldering …………:
No such thermal device
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
……………………………………………….......:
60127
……………………………………………….......:
Fuses are approved
components according to
IEC 60127.
See appended table, list of
critical components.
components according to
IEC 60127.
See appended table, list of
critical components.
P
14.5.2.2
Correct marking of fuse-links adjacent to
holder ……:
holder ……:
The following marking applied;
Mains fuses;
F901: T6.3A L 250V
F902: T2.5A L 250V
F901: T6.3A L 250V
F902: T2.5A L 250V
Secondary fuse;
F110: T5A L 250V
F111: T5A L 250V
F110: T5A L 250V
F111: T5A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ………….:
No fuse holder so designed
that fuse-links can be
connected in parallel
that fuse-links can be
connected in parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ……..:
replacing fuse-links without the use of a tool ……..:
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
……….:
……….:
No PTC’s thermistors.
N/A
Click on the first or last page to see other AVR 460 (serv.man2) service manuals if exist.