Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3 ………………:
See 13.3
P
Creepage distances in accordance with 13.4 …….:
See 13.4
P
13.2
Determination of operating voltage …..……:
Conventional
linear transf. used.
Rated supply voltage (240V)
applied in determining the
operating voltage.
applied in determining the
operating voltage.
P
13.3 Clearances
2N for internal parts and 30N
for enclosures are considered
when determining clearances.
for enclosures are considered
when determining clearances.
P
13.3.1 General
…………………………:
Considered
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ………..:
with table 8 and, where applicable, table 9 ………..:
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10 ……………...:
comply with table 10 ……………...:
No hazardous secondary
voltages
voltages
N/A
13.3.4
Measurement of transient voltages ………..:
No measurement of transient
voltages
voltages
N/A
13.4
Creepage distances ……………...:
CTI > 100
(see appended table 13)
(see appended table 13)
P
Creepage distances greater than table 11 minimum
values …………………...:
values …………………...:
Not applicable
N/A
13.5
Printed boards
Refer to below
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10 ……………………:
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10 ……………………:
No such PCB used
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only) ………..:
IEC 60664-3 (basic insulation only) ………..:
No type B coated printed
circuit boards
circuit boards
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4 ………….............:
clearances and creepage distances comply with
13.3 and 13.4 ………….............:
No uncemented joints
N/A
Conductive parts along reliably cemented joints
comply with 8.8 ………………:
comply with 8.8 ………………:
N/A
Temperature cycle test and dielectric strength test :
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12:
not conductively connected to the mains, clearances
and creepage distances as in table 12:
No enclosed, enveloped or
hermetically sealed parts
hermetically sealed parts
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8 ………………………:
requirements of 8.8 ………………………:
No parts filled with insulating
compound.
compound.
N/A