Read Harman Kardon AVR 460 (serv.man2) EMC - CB Certificate online
- Page 17 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13 ……………………………..:
clause 13 ……………………………..:
(see appended table 13)
P
14.3.3.2 Transformers
meet
the constructional requirements:
(see appended table 14.3.3)
P
14.3.4
Separation between windings
P
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
Double or reinforced
insulation between primary
and secondary windings
according to clause 8.8.
(see appended table 14.3.3)
insulation between primary
and secondary windings
according to clause 8.8.
(see appended table 14.3.3)
P
Coil formers and partition walls > 0,4 mm ……...:
Main and Sub transf. bobbin
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met ……………………………………….:
protective screening only if all 7 conditions of
14.3.4.2 are met ……………………………………….:
Class II apparatus.
No such transformer used.
No such transformer used.
N/A
14.3.4.3
Separating transformers with at least basic
insulation:
insulation:
Windings of Class II
construction used.
construction used.
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm ………...:
Main and Sub transf. bobbin
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal …………………………………………………:
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal …………………………………………………:
Winding of Class II
construction used.
construction used.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity ………………..:
adequate current-carrying capacity ………………..:
N/A
14.4
High voltage components …………………………..:
No high-voltage components.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved ………….....................:
(peak) separately approved ………….....................:
N/A