AVR 460 (serv.man2) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 21

Read Harman Kardon AVR 460 (serv.man2) EMC - CB Certificate online

 
 
- Page 17 of 44 - 
 
 
 
 
 Report 
No. 
129952 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
14.3.3 
Constructional requirements  
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 ……………………………..: 
(see appended table 13) 
14.3.3.2 Transformers 
meet 
the constructional requirements:
(see appended table 14.3.3) 
14.3.4 
Separation between windings 
 
 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) …………………...: 
Double or reinforced  
insulation between primary 
and secondary windings 
according to clause 8.8. 
(see appended table 14.3.3) 
 
Coil formers and partition walls > 0,4 mm ……...: 
Main and Sub transf. bobbin 
fulfils the requirement of 
reinforced insulation; bobbin 
thickness > 0,4 mm. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met ……………………………………….:
Class II apparatus.  
No such transformer used. 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation: 
Windings of Class II 
construction used. 
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) …………………...: 
Double or reinforced insulation  
between hazardous live  
windings and accessible  
conductive parts. 
 
Coil formers and partition walls > 0,4 mm ………...: 
Main and Sub transf. bobbin 
fulfils the requirement of 
reinforced insulation; bobbin 
thickness > 0,4 mm. 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal …………………………………………………:
Winding of Class II  
construction used. 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity ………………..: 
 
N/A 
14.4 
High voltage components …………………………..: 
No high-voltage components. 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved ………….....................: 
 
N/A 