Read Harman Kardon AVR 460 (serv.man2) EMC - CB Certificate online
- Page 21 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.10 Batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases ………………………………………:
flammable gases ………………………………………:
No batteries.
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries ………………………………………………:
batteries ………………………………………………:
N/A
14.10.3
Recharging currents and times within manufacturers
limits …………………………………………………….:
limits …………………………………………………….:
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits ……………………….:
within the manufacturers limits ……………………….:
N/A
14.10.4
Battery mould stress relief ………………………….:
N/A
14.10.5
Battery drop test ……………………………………..:
N/A
14.11 Optocouplers
No optocouplers
N/A
Optocouplers comply with Cl. 8 ………………………:
N/A
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation) ………………:
alternatively 13.6 (jointed insulation) ………………:
N/A
14.12
Surge suppression varistors
No surge suppression varistors
N/A
Comply with IEC 61051-2 …………………………..:
N/A
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus …………………………………………….:
except for earthed parts of permanently connected
apparatus …………………………………………….:
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12 ………………..:
thermal stress requirements of 14.12 ………………..:
N/A
15 Terminals
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard …………………………………...:
and mains socket-outlet meet the appropriate
standard …………………………………...:
Approved appliance inlet,
mains plug/coupler and
mains socket outlet provided.
See appended table, list of
critical components
mains plug/coupler and
mains socket outlet provided.
See appended table, list of
critical components
P
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets …………..:
the apparatus has mains socket outlets …………..:
Prevented by the fuse;
F902 (T 2.5A L 250V)
F902 (T 2.5A L 250V)
P
Overloading of internal wiring prevented if the
apparatus has mains socket outlets ………….:
apparatus has mains socket outlets ………….:
Prevented by the fuse;
F902 (T 2.5A L 250V)
F902 (T 2.5A L 250V)
P
15.1.2
Connectors for antenna, earth, audio, video or
data .:
data .:
P
Click on the first or last page to see other AVR 460 (serv.man2) service manuals if exist.