- Page 20 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1 …………………….:
additional tests to IEC 60058-1 …………………….:
Measured inrush current
through mains switch is
through mains switch is
< 1 A.
The measured inrush current
is less than rated current of
the mains switch (6A) - O.K..
is less than rated current of
the mains switch (6A) - O.K..
Measured inrush current
through mains relay;
19A + 20 A * = 39 A
*) Added current for socket
outlet (
through mains relay;
19A + 20 A * = 39 A
*) Added current for socket
outlet (
Socket outlet current
marking
: 0.5 A).
The measured inrush current
value is less than rated inrush
current rating of the mains
relay (100A). - O.K.
value is less than rated inrush
current rating of the mains
relay (100A). - O.K.
(The mains socket outlet is
controlled by the mains relay).
controlled by the mains relay).
P
Socket outlet current marking correct …………..:
Socket outlet marking:
SWITCHED (50W, 0.5A MAX)
SWITCHED (50W, 0.5A MAX)
P
14.7
Safety interlocks
N/A
Safety interlocks to 2.8 of IEC 60950 …………......:
No safety interlock
N/A
14.8
Voltage setting devices and the like ……………….:
No voltage setting devices.
N/A
Voltage setting device not likely to be changed
accidentally ………………………………………......:
accidentally ………………………………………......:
N/A
14.9 Motors
Low voltage DC fan motors.
P
14.9.1
Endurance test on motors …………………………….:
N/A
Motor start test …………………………………………:
N/A
Dielectric strength test ………………………………:
N/A
14.9.2
Not adversely affected by oil or grease etc. ………..:
The fans are not adversely
affected by oil, grease or other
substances.
affected by oil, grease or other
substances.
P
14.9.3
Protection against moving parts ………………...:
The fans are placed inside the
unit. No access.
unit. No access.
P
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B ……………………….:
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B ……………………….:
No such construction.
The fans are low voltage DC
components only.
The fans are low voltage DC
components only.
N/A