- Page 22 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
No risk of insertion in mains socket-outlets ….:
Only RCA, Antenna, Optical,
HDMI, USB,
HDMI, USB,
A-BUS,
Mini jack
terminal used.
Banana play type speaker
terminal also used, but they
are accepted due to below
note.
Note) Banana type speaker
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
Banana play type speaker
terminal also used, but they
are accepted due to below
note.
Note) Banana type speaker
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2 …......................:
marked with the symbol of 5.2 …......................:
No sockets indicated with
the symbol
the symbol
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets :
not compatible with household mains socket-
outlets :
The equipment under test is
not an adaptor.
not an adaptor.
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II apparatus.
N/A
Protective earth conductors correctly coloured …..:
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
….................................................................:
provided with separate protective earth terminal
near mains input
….................................................................:
N/A
Protective earth terminal resistant to corrosion …..:
N/A
Earth resistance test: < 0,1
Ω at 25 A ……….:
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
N/A
15.3.1
Adequate terminals for connection of permanent
wiring ……………………………………………...….:
wiring ……………………………………………...….:
Appliance inlet applied
N/A
15.3.2
Reliable connection of non-detachable cords …….:
N/A
Not soldered to conductors of a printed circuit
board :
board :
N/A
Adequate clearances and creepage distances
between connections should a wire break away …:
between connections should a wire break away …:
N/A
Wire secured by additional means to the conductor:
N/A