IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
 
d) Energy of discharge not exceeding 350 mJ ..: 
No part or contact of a terminal 
with stored voltages exceeding 
15kV. 
N/A 
9.1.1.2 
Test with test finger and test probe …...: 
No access to hazardous  
live parts 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers: 
No live shaft, handles or levers 
N/A 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin 
………………………………: 
No access for the test pin  
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032 …………………: 
Does not reach hazardous live 
parts 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 ……: 
Does not reach hazardous live 
parts 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
……………….: 
No preset controls 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 
2 s …: 
See below, 
N/A 
 
If C is not greater than 0,1 μF no test needed ……: 
<
 0,1 μF 
9.1.7 
Resistance to external forces
 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N) …...: 
Test with test finger  
result in no hazard 
 
b) Test hook of fig. 4 for 10 s (20 N) 
…………………: 
Test with test hook results in  
no hazard. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N) 
 .............................................................................. …: 
Tested with 100N results in  
no damage. 
9.2 
No hazard after removing a cover by hand ……….: 
No cover removable by  
hand 
N/A 
 