Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online
- Page 15 of 42 -
Report No. 98388
13.5 Printed
boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
No such PCB used.
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
No type B coated printed
circuit boards.
circuit boards.
N/A
13.6
Conductive parts along uncemented joints clearances
and creepage distances comply with 13.3 and 13.4
and creepage distances comply with 13.3 and 13.4
No uncemented joints.
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
13.7
Enclosed, enveloped or hermetically sealed parts: not
conductively connected to the mains: clearances and
creepage distances as in table 12
conductively connected to the mains: clearances and
creepage distances as in table 12
No such part used.
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
No such part used.
N/A
14 COMPONENTS
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors.
N/A
b) Resistors, other than between hazardous live parts
and accessible parts
and accessible parts
Not used.
N/A
Resistors
separately approved ............................... :
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes, see below.
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ... :
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ... :
C904 is certified X capacitor
by IEC 60384-14, 2
by IEC 60384-14, 2
nd
edition
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No such capacitors.
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ................... :
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ................... :
Several E. cap.
Vol. >1750mm
Vol. >1750mm
3
, but metal
cases.
N/A