Report No.  98388 
 
 
 
b) Test hook of fig. 4 for 10 s (20 N) 
Test with test hook result 
in no hazard. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  : 
Tested with 100N result 
in no damage. 
9.2 
No hazard after removing a cover by hand 
No cover removable by 
hand. 
N/A 
 
 
 
 
10 INSULATION 
REQUIREMENTS 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation  ................................................................. : 
> 100MΩ, after surge test 
10.2 Humidity 
treatment 48 h or 120 h  ........................... : 
Performed for 120h at  
temp. 40°C and relative  
humidity 93%. 
10.3 
Insulation resistance and dielectric strength between 
mains teminals 
See appended table 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1) 
Class II apparatus. 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II) 
See appended table 
 
 
 
11 FAULT 
CONDITIONS 
11.1 
No shock hazard under fault condition 
No electric shock hazard 
under fault conditions. 
11.2 
Heating under fault condition 
See attachment, Tables to 
EN/IEC 60065 7
th
 edition. 
 
No hazard from softening solder 
No softening of solder. 
 
Flames extinguish within 10 seconds 
No flames. 
 
Soldered terminations not used  as protective 
mechanism 
No soldered terminations. 
11.2.1 
Measurement of temperature rises 
See appended table. 
11.2.2 
Temperature rise of accessible parts 
See appended table. 
 