Report No. 98388
b) Test hook of fig. 4 for 10 s (20 N)
Test with test hook result
in no hazard.
in no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N) :
Tested with 100N result
in no damage.
in no damage.
P
9.2
No hazard after removing a cover by hand
No cover removable by
hand.
hand.
N/A
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
> 100MΩ, after surge test
P
10.2 Humidity
treatment 48 h or 120 h ........................... :
Performed for 120h at
temp. 40°C and relative
humidity 93%.
temp. 40°C and relative
humidity 93%.
P
10.3
Insulation resistance and dielectric strength between
mains teminals
mains teminals
See appended table
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
Class II apparatus.
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
See appended table
P
11 FAULT
CONDITIONS
P
11.1
No shock hazard under fault condition
No electric shock hazard
under fault conditions.
under fault conditions.
P
11.2
Heating under fault condition
See attachment, Tables to
EN/IEC 60065 7
EN/IEC 60065 7
th
edition.
P
No hazard from softening solder
No softening of solder.
P
Flames extinguish within 10 seconds
No flames.
P
Soldered terminations not used as protective
mechanism
mechanism
No soldered terminations.
P
11.2.1
Measurement of temperature rises
See appended table.
P
11.2.2
Temperature rise of accessible parts
See appended table.
P