Report No.  98388 
 
 
 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  .... : 
The following marking applied; 
F901: T6.3A L 250V 
F902; T2.5A L 250V 
F110, F111: T2.5A L 250V 
14.5.2.3 
Not possible to connect fuses in parallel  ................ : 
No possible to connect  
fuses in parallel. 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ......... : 
No replacement of fuses 
possible by hand. 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
None 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
None 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
No other protective devices. 
N/A 
14.6 Switches 
 
14.6.1 a)  Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
Make and break speed independent of speed of 
actuation 
V-0 compliance with annex G, G.1.1 
Yes,  
Mains switch and relay  
provided. Certified according  
to IEC61058-1. 
- Mains switch, certified by  
  FIMKO 
- Mains relay certified by  
  SEMKO 
See list of critical components. 
14.6.1 b)  Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage > 
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and 
V-0 in annex G, G.1.1 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage < 
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in 
annex G, G.1.1 
 
N/A 
 
Switch controlling < 0.2A with open contact  voltage > 
35 V (peak)/24 V dc complying with  14.6.4 and V-0 in 
annex G, G.1.1 
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-1 
subclause 13.1 and has making/breaking  action 
independent of speed of actuation 
Separately approved switch 
and relay. 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-1 
subclause 16.2.2 d) and  m) not attaining excessive 
temperatures in use 
Separately approved switch 
and relay. 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
Separately approved switch 
and relay. 