Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online
- Page 18 of 42 -
Report No. 98388
14.5.2.2
Correct marking of fuse-links adjacent to holder .... :
The following marking applied;
F901: T6.3A L 250V
F902; T2.5A L 250V
F110, F111: T2.5A L 250V
F901: T6.3A L 250V
F902; T2.5A L 250V
F110, F111: T2.5A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ................ :
No possible to connect
fuses in parallel.
fuses in parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuses
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
None
N/A
PTC-S devices (15 W) category V-1 or better
None
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
No other protective devices.
N/A
14.6 Switches
P
14.6.1 a) Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
Normal pollution suitability
Resistance to heat and fire level 3
and
Make and break speed independent of speed of
actuation
actuation
V-0 compliance with annex G, G.1.1
Yes,
Mains switch and relay
provided. Certified according
to IEC61058-1.
- Mains switch, certified by
FIMKO
- Mains relay certified by
SEMKO
See list of critical components.
Mains switch and relay
provided. Certified according
to IEC61058-1.
- Mains switch, certified by
FIMKO
- Mains relay certified by
SEMKO
See list of critical components.
P
14.6.1 b) Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and
V-0 in annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and
V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage <
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage >
35 V (peak)/24 V dc complying with 14.6.4 and V-0 in
annex G, G.1.1
35 V (peak)/24 V dc complying with 14.6.4 and V-0 in
annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-1
subclause 13.1 and has making/breaking action
independent of speed of actuation
subclause 13.1 and has making/breaking action
independent of speed of actuation
Separately approved switch
and relay.
and relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-1
subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
Separately approved switch
and relay.
and relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved switch
and relay.
and relay.
N/A