Report No. 98388
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltages exceeding
1000V ac or 1500V dc
1000V ac or 1500V dc
N/A
9.1.1.1
a) Open circuit voltages
Mains input voltage >35V
see below.
see below.
—
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
See attachment, Table to
EN/IEC 60065 7
EN/IEC 60065 7
th
Edition.
P
c) Discharge not exceeding 45 μC
No part or contact of a
terminal with stored
voltages between 60V-15kV
terminal with stored
voltages between 60V-15kV
N/A
d) Energy of discharge not exceeding 350 mJ
No part or contact of
a terminal with stored
Voltages exceeding 15kV.
a terminal with stored
Voltages exceeding 15kV.
N/A
9.1.1.2
Test with test finger and test probe
No access to hazardous
live parts.
live parts.
P
9.1.2
No hazardous live shafts of knobs, handles or levers
No live shaft handles or
levers.
levers.
P
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Does not reach hazardous
live parts.
live parts.
P
Terminal devices tested with 1 mm x 100 mm straight
wire (1 N); test probe D of IEC 61032
wire (1 N); test probe D of IEC 61032
Does not reach hazardous
live parts.
live parts.
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test pin
(10 N); test probe C of IEC 61032
(10 N); test probe C of IEC 61032
No preset controls.
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s ................... :
of the mains plug; voltage (V) after 2 s ................... :
See below
N/A
If C is not greater than 0,1 μF no test needed
< 0,1uF
N/A
9.1.7
a) Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger result
in no hazard.
in no hazard.
P