Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online
- Page 17 of 42 -
Report No. 98388
Coil formers and partition walls > 0,4 mm
The bobbin fulfils the
requirement of reinforced
insulation;
bobbin thickness > 0.4 mm
requirement of reinforced
insulation;
bobbin thickness > 0.4 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Class II transformer provided.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No high-voltage components.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5 Protective
devices
P
Protective devices used within their ratings
Approved fuses and thermal
links.
links.
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Adequate external clearance
and creepage distance.
and creepage distance.
P
14.5.1.1
a) Thermal cut-outs separately approved
None.
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
Thermal links in main and
sub transformer are separately
approved component.
See list of critical components.
sub transformer are separately
approved component.
See list of critical components.
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal devices
re-settable by soldering.
re-settable by soldering.
P
14.5.2.1
Fuse-links in the mains circuit according to IEC 60127
Fuses are approved
components according to
IEC 60127.
See list critical components.
components according to
IEC 60127.
See list critical components.