Report No.  98388 
 
 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
Measured inrush current 
through mains switch is 
< 1 A. 
The measured inrush current 
is less than rated current of 
the mains switch (6A) - O.K.. 
 
Measured inrush current 
through mains relay =  
 = 37A + 20 A * 
*) Added current for socket 
outlet marked “0.5 A”. 
 
The measured inrush current 
value is less than rated inrush 
current rating of the mains 
relay (120A). - O.K. 
 
(The mains socket outlet is 
controlled by the mains relay). 
 
Socket outlet current marking correct 
Socket outlet marking: 
SWITCHED (50W, 0.5A MAX) 
N/A 
14.7 Safety 
interlocks 
No safety interlock 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 
 
N/A 
14.8 
Voltage setting devices 
and the like
 
No voltage selector 
N/A 
 
Voltage setting device not likely to be changed 
accidentally 
 
N/A 
14.9 Motors 
DC brush-less fan motor 
14.9.1 
Endurance test on motors 
 
N/A 
 
Motor start test 
 
N/A 
 
Dielectric strength test 
Only DC supplied 
N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
The fans are not adversely 
affected by oil, grease or  
other substances. 
14.9.3 
Protection against moving parts 
The fan is placed inside the 
unit.  No access. 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950, Annex B 
 
N/A 
 