AVR 355 (serv.man6) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 18

Read Harman Kardon AVR 355 (serv.man6) EMC - CB Certificate online

 
 
- Page 10 of 42 - 
 
 
 
 
Report No.  98388 
 
 
8.11 
Detaching of wires 
 
 
No undue reduction of creepages or clearance  
distances if wires become detached 
One end of inlet and switch 
connected wires are hooked- 
in before soldered. 
Other ends of inlet and switch 
connected wires are  
connected with multi-contact 
housing. 
 Vibration 
test carried out  ......................................... : 
See 12.1.2 
8.12 
This clause is void 
 
— 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s) 
Adequately fastened. 
8.14 
Adequate fastening of covers (pull test 50 N for 10 s) 
Covers adequately fastened 
with screws. 
8.15 
No risk of damage to the insulation of internal wiring  
due to hot parts or sharp edges 
Wires safely anchored 
away from parts with high 
temperature and sharp edges 
8.16 
Only special supply equipment can be used 
No supplied by a special 
supply apparatus. 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation 
No such components. 
N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
See below 
8.19.1 Disconnect 
device 
Appliance coupler is  
disconnection device 
 
All-pole switch or circuit breaker with >3mm contact se
paration 
No all-pole switch and circuit 
breaker. 
N/A 
8.19.2 
Mains switch ON indication 
Indicator lamp or FL display 
lit-on for mains switch ON  
indication, but switch is single 
pole only. 
8.20 
Switch not fitted in the mains cord 
 
8.21 
Bridging components comply with clause 14 
Yes, relay across the capacitor 
is certified component. 
See appended table, list of  
critical components. 
8.22 
Non-separable thin sheet material 
No non-separable thin  
sheet material. 
N/A 
 
Page of 58