Read Harman Kardon AVR 158 (serv.man6) EMC - CB Certificate online
Page 19 of 46
Report No.: 162888
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3
See 13.3
P
Creepage distances in accordance with 13.4
See 13.4
P
13.2
Determination of operating voltage
Conventional transformer used.
Upper rated supply voltage
(240V) applied in determining
the operating voltage
Upper rated supply voltage
(240V) applied in determining
the operating voltage
P
13.3
Clearances
2N for internal parts and
30N for enclosure are
considered when determining
clearances.
30N for enclosure are
considered when determining
clearances.
P
13.3.1
General
Considered
P
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9..:
comply with table 8 and, where applicable, table 9..:
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
No hazardous secondary
voltages
voltages
N/A
13.3.4
Measurement of transient voltages
No measurement of
transient voltages
transient voltages
N/A
13.4
Creepage distances
CTI > 100
(see appended table 13)
(see appended table 13)
P
Creepage distances greater than table 11 minimum
values
values
Not applicable
N/A
13.5
Printed boards
Refer to below
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
No such PCB used
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
No type B coated printed
circuit boards
circuit boards
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
No uncemented joints
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains,
clearances and creepage distances as in table 12
not conductively connected to the mains,
clearances and creepage distances as in table 12
No such part used
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
No such part used
N/A
Click on the first or last page to see other AVR 158 (serv.man6) service manuals if exist.