Read Harman Kardon AVR 158 (serv.man6) EMC - CB Certificate online
Page 23 of 46
Report No.: 162888
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.6
Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
Mains switch and relay provided.
Certified according to
IEC 61058-1.
Certified according to
IEC 61058-1.
See appended table,
list of critical components.
list of critical components.
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
Separately approved switch
and relay.
and relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Separately approved switch
and relay.
and relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved switch
and relay.
and relay.
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
The apparatus is not provided
the socket outlet, but
measured the apparatus inrush
current through,
- Mains relay: 17.4 A peak
- Mains switch: < 1 A peak
the socket outlet, but
measured the apparatus inrush
current through,
- Mains relay: 17.4 A peak
- Mains switch: < 1 A peak
The measured inrush current
value is;
- less than rated inrush current
rating for mains relay (100A),
- less than rated current
rating for mains switch (6A).
value is;
- less than rated inrush current
rating for mains relay (100A),
- less than rated current
rating for mains switch (6A).
P
Socket outlet current marking correct
No mains socket-outlets
N/A
14.7
Safety interlocks
No safety interlocks
N/A
Safety interlocks to 2.8 of IEC 60950
N/A