Report No.: 162888
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.21
Bridging components comply with clause 14
C904capacitor, bridging
contact gaps of the mains relay
Certified component.
See appended table, list of
critical components.
contact gaps of the mains relay
Certified component.
See appended table, list of
critical components.
P
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltage exceeding
1000V ac or 1500V dc.
1000V ac or 1500V dc.
N/A
9.1.1.1
a) Open circuit voltages
Mains input voltage >35 Vac,
see below.
see below.
—
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
(see appended table 9.1.1.1)
P
c) Discharge not exceeding 45
μC
No part or contact of a
terminal with stored voltages
between 60 V – 15 kV.
terminal with stored voltages
between 60 V – 15 kV.
N/A
d) Energy of discharge not exceeding 350 mJ
No part or contact of a terminal
with stored voltages exceeding
15 kV.
with stored voltages exceeding
15 kV.
N/A
9.1.1.2
Test with test finger and test probe
No access to hazardous
live parts
live parts
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
No live shafts knobs, handles
or levers.
or levers.
P
9.1.3
Ventilation holes and other holes tested by means
of 4 mm x 100 mm test pin
of 4 mm x 100 mm test pin
No access for the test pin.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Does not reach hazardous
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Does not reach hazardous
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls.
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
See below
N/A
If C is not greater than 0,1
μF no test needed
< 0.1uF
—
9.1.7
Resistance to external forces
P