AVR 158 (serv.man6) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 27

Read Harman Kardon AVR 158 (serv.man6) EMC - CB Certificate online

 
 
 
Page 21 of 46 
 
Report No.: 162888 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
14.3.3.2 
Transformers meet the constructional requirements  (see appended table 14.3.3)
 
14.3.4 
Separation between windings 
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)   : 
Double or reinforced  
insulation between primary 
and secondary windings 
according to clause 8.8. 
(see appended table 14.3.3)
 
 
Coil formers and partition walls > 0,4 mm  
Main and Sub transf. bobbin 
fulfils the requirement of 
reinforced insulation: bobbin 
thickness > 0.4 mm. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met  
Class II apparatus. 
No such transformer used. 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
Windings of Class II 
construction used. 
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
Double or reinforced insulation 
between hazardous live 
windings and accessible 
conductive parts 
 
Coil formers and partition walls > 0,4 mm  
Main and Sub transf. bobbin 
fulfils the requirement of 
reinforced insulation: bobbin 
thickness > 0.4 mm. 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
Windings of Class II 
construction used. 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 
N/A 
14.4 
High voltage components  
No high-voltage components 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 
N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 
N/A 
Page of 85