Read Harman Kardon AVR 158 (serv.man6) EMC - CB Certificate online
Page 14 of 46
Report No.: 162888
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class II equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging double or reinforced
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
The equipment has isolating
transformers complies with
clause 14.3
transformers complies with
clause 14.3
P
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
No such components
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
No such capacitors
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
No such capacitors
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
No such capacitors
N/A
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm)..:
No such components
N/A
Reinforced insulation > 0,4 mm (mm) .................... : Bobbins in main and sub
transformer
(see appended table 14.3.3)
(see appended table 14.3.3)
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
No thin sheet insulation
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulated
P