AVR 158 (serv.man6) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 28

Read Harman Kardon AVR 158 (serv.man6) EMC - CB Certificate online

 
 
 
Page 22 of 46 
 
Report No.: 162888 
 
 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
 
 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 
N/A 
14.5 
Protective devices  
 
 
Protective devices used within their ratings  
Thermal link and fuses 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
Certified protective devices 
applied (thermal-links and  
fuses). 
See appended table, 
list of critical components. 
14.5.1.1 
a) Thermal cut-outs separately approved  
No thermal cut-outs. 
N/A 
 
b) Thermal cut-outs tested as part of the submission   
N/A 
14.5.1.2 
a) Thermal links separately approved  
Thermal link in main transf., 
separately approved compo. 
See appended table, list of 
critical components. 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
No thermal device 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
Fuses are approved component 
according to IEC 60127. 
See appended table, list of 
critical components. 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... :  The following marking applied; 
 
Mains fuses;  
F901: T4A L 250V  
 
Secondary fuse;  
F110: T3.15A L 250V 
F111: T3.15A L 250V 
14.5.2.3 
Not possible to connect fuses in parallel  ................ :  No fuses holder so designed 
that fuse-links can be  
connected in parallel. 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ......... : 
No replacement of fuses 
possible by hand. 
14.5.3 
PTC thermistors comply with IEC 60730-1  
No PTC`s thermistors 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked  
Only standard fuses used. 
N/A 
Page of 85
Display