Read Harman Kardon AVR 158 (serv.man6) EMC - CB Certificate online
Page 22 of 46
Report No.: 162888
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
P
Protective devices used within their ratings
Thermal link and fuses
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
Certified protective devices
applied (thermal-links and
fuses).
See appended table,
list of critical components.
applied (thermal-links and
fuses).
See appended table,
list of critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved
No thermal cut-outs.
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
Thermal link in main transf.,
separately approved compo.
See appended table, list of
critical components.
separately approved compo.
See appended table, list of
critical components.
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal device
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are approved component
according to IEC 60127.
See appended table, list of
critical components.
according to IEC 60127.
See appended table, list of
critical components.
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : The following marking applied;
Mains fuses;
F901: T4A L 250V
F901: T4A L 250V
Secondary fuse;
F110: T3.15A L 250V
F111: T3.15A L 250V
F110: T3.15A L 250V
F111: T3.15A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ................ : No fuses holder so designed
that fuse-links can be
connected in parallel.
connected in parallel.
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuses
possible by hand.
possible by hand.
P
14.5.3
PTC thermistors comply with IEC 60730-1
No PTC`s thermistors
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
Only standard fuses used.
N/A
Click on the first or last page to see other AVR 158 (serv.man6) service manuals if exist.