– 13 –
KV-HV212M50/M53
   RM-GA002
2-14.  Conn Assy, 7P, UL Wire (1-923-000-81), Lead Assy, Earth & Rotational Coil Conn Dressing
2-15.  HV Cap Assy Dressing
Dress Conn Assy, 7P, UL Wire (1-923-000-81), Lead Assy, Earth, 
Dress Conn Assy, 7P, UL Wire (1-923-000-81), Lead Assy, Earth, 
Conn Assy, 3P(1-900-703-83), Rotational Coil Conn with purse lock, Ø9 as shown.
and Rotational Coil Conn with purse lock, Ø5 as shown.
Note : Keep Lead Assy, Earth away from heat sinks. 
Note : Keep Lead Assy, Earth away from heat sinks. 
Purse Lock Ø9
Lead Assy,
Earth
Conn Assy, 7P
UL Wire (1-923-000-81)
Conn Assy,
3P
Rotational Coil
Conn
3D Models
Non 3D Models
Rotation Coil
DY
90
Purse Lock Ø5
Keep Lead Assy, Earth away
from heat sinks
Conn Assy, 7P
Rotational
Coil Conn
Lead Assy, Earth
A:  Conn Assy, 7P
B:  Lead Assy, Earth
C:  UL Wire (1-923-000-81)
D: Rotational Coil Conn
E: Conn Assy, 3P (woofer)
A      B    C   D  E
Rotational Coil & 3D Models
Purse Lock Ø9
A:  Conn Assy, 7P
B:  Lead Assy, Earth
C:  UL Wire (1-923-000-81)
D: Rotational Coil Conn
A    B     C    D 
Rotational Coil & Non-3D Models
Purse Lock Ø5
1) Dress HV cap assy with HV Holder as shown
     Note: Make sure the specified position is being followed.
2) Dress HV holder at DGC with purse lock, Ø9 as shown
3) Using Yellow line (CRT Carbon line) as a reference to dress purse lock, Ø9.
CAUTION:
OK
NG
Ensure HV Holder is beside
DGC to keep further distance 
from HV Cable
distance > 1mm/kV
distance < 1mm/kV
180 ± 5 mm
HV Cable Holder
Place purse lock Ø9 after the exit of DGC Conn from DGC
DGC
Purse Lock Ø9
Black tape
DGC Conn outlet
Gate (2 positions)
of HV holder
Dress HV Cable at inner ring
SAFETY
OPERATION
45º
Min. distance = 1mm/kV
Min. distance = 1mm/kV
Min. distance =
0.5mm/kV
CRT Carbon
Area
TVSR requirement:
1. Spacing between HV cable and other conductive part’s surface is 1mm/kV or more.
2. Spacing between HV cable's and enclosure with ventilation or the edge where
  terminal bracket and rear cover meet: 10 mm or more.
3. Spacing between edge of anode cap and conductive parts is 0.5mm/kV or more
Keep wires away
from heat sinks
UL Wire (1-923-000-81)
Wire from
Rotation Coil
Page of 67