2-12.  DY Conn & Conn Assy, 5P (200V) Dressing
2-13.  Lead Assy, G2 & Focus Dressing
DY Conn & Conn Assy, 5P (200V) dressing
1) Dress DY Conn along Conn Assy, 5P (200V) as shown. 
2) Dress DY Conn and Conn Assy, 5P (200V) with Purse Lock Ø5.
     Note : Keep DY Conn & Conn Assy, 5P away from FBT area by a distance of 10mm or more.
DY Conn goes underneath of 
Earth Assy, Coating and Conn
Assy, 5P (200V)
1
2
DY Conn goes above Conn Assy, 5P (200V).
DY Conn
Conn Assy, 5P (200V)
Earth Assy, Coating
Purse Lock Ø5
DY Conn
Conn Assy, 5P
 (200V)
Use heat sink height to
estimate purse lock location
Purse Lock Ø5
≥ 10mm
3
Dress DY Conn and Conn Assy, 5P
(200V) with Purse Lock Ø5.
TVSR Requirement :
All wires must be kept away from
FBT area by a distance of 10mm or
more
Dress Earth Assy, Coating, Lead Assy, G2 & Focus with purse lock Purse Lock Ø5. as shown
Note : Keep Lead Assy, G2 away from HV Cable (min 1mm/kV)
          Ensure Lead Assy, G2 is kept away from heat sinks
Purse lock dia.5
FBT 
(G2)
CN704
(C)
ECA
FBT 
(Focus) 
CRT 
SOCKET
CN705
(C)
Lead Assy, Focus
Lead Assy, G2
Keep Lead Assy, G2
away from Heat Sink.
Keep Lead Assy, G2
away from HV Cable
(at least 1mm/kV)
Dress tight at the portion to avoid
wire touches rear cover .
Rear view of Lead Assy, Focus & G2, connected
from FBT A brd to C brd.
Lead Assy, G2
Lead Assy, Focus
Conn. Assy, 5P (200v)
Earth Assy, Coating
TVSR requirement :
1. Spacing between HV cable and other conductive part’s surface is 1mm/kV or more.
2. Spacing between HV cable's and enclosure with ventilation or the edge where
 
terminal bracket and rear cover meet: 10 mm or more.
SAFETY
OPERATION
Purse Lock, dia.5
Use this as a reference to dress
ECA, Lead Assy, Focus & G2.
Make sure DY Conn is on the right
side of Earth Assy, Coating
Page of 67