KV-HP213M83 (serv.man2) - Sony TV Service Manual (repair manual). Page 10

Read Sony KV-HP213M83 (serv.man2) Service Manual online

– 9 –
KV-HP213M83
   RM-GA002
2-4.  INSERT DUMMY CONNECTOR TO CN600 (A PWB)
2-5.  INSERT EARTH COATING ASSY TO CN705 (C PWB)
2-6.  INSTALL C PWB TO CRT NECK
1. Insert Dummy connector to CN600 (A PWB)
Dummy Connector
OK
NG-Lifted
1.  Make a loop with ECA around the DGC and pull toward 
 
C brd when connecting as in Figure 1 & 2.
2.  Insert Earth Coating Assy connector to CN705 (CPWB) 
 
as in Figure 3.
3.  Pull & Push Earth Coating assy, Conn. (1x) to ensure its 
 
lock on C pwb.
CN705 (C PWB)
Coating Earth Assy
DGC Coil 
OK
NG-LIFTED
1. Install C PWB to CRT neck
2. Push the C PWB towards CRT.
CRT socket printed
Space Between C PWB 
& Conn. Assy 7P
CAUTION:
Make sure Dummy Connector is fully inserted to ensure degaussing is
functioning during adjustment process in progress.
CAUTION:
1. Make sure Earth Assy, Coating, Conn. is completely locked.
2. Make sure Earth Assy, Coating is not too tight on C PWB.
CAUTION:
Make sure the CRT socket is properly installed into the CRT neck.
Pull up Conn. Assy 7P to give space for G2 jig.