– 11 –
KV-HP213M83
   RM-GA002
2-10.  DRESS CONN. ASSY 7P, LEAD ASSY EARTH, UL WIRE & ROTATIONAL COIL CONN WITH PURSE LOCK Ø5
2-11.  DRESS CONN. ASSY 7P, LEAD ASSY EARTH & UL WIRE WITH PURSE LOCK Ø5
2-12.  DRESS CONN. DY, CONN. ASSY 5P WITH PURSE LOCK Ø5
1. Dress Conn. Assy 7P, Lead Assy Earth, UL wire & Rotational Coil  Conn with Purse Lock Ø5 as shown.
Purse Lock Ø5
Lead Assy 
UL wire 91-923-000-81
Keep Lead Assy, Earth away from heat sinks
Conn. Assy 7P
Lead Assy Earth
UL wayar
Purse Lock Ø5
CN004
(A PWB)
1. Dress Lead Assy, Speaker, Conn. Assy, 3P, Rotational Coil Conn.,
  Conn. Assy, 7P, Lead Assy, Earth & UL tape with purse Ø9
  as shown.
Purse Lock
Ø9
Keep Lead Assy, Earth
away from heat sinks
Lead Assy,
Earth
Conn Assy, 7P
UL Wire (1-923-000-81)
Connector Assy, 3P
Lead Assy, Speaker
Rotational Coil Conn.
Lead Assy, Earth
Connector Assy, 7P
                  UL Wire
 Rotational Coil Conn.
Lead Assy, Speaker
Connector Assy, 3P
Purse Lock Ø9
1. Dress Conn. DY, Conn. Assy 5P with Purse Lock Ø5 (1x)  as shown.
TVSR REQUIREMENT
1)Make sure the distance between connector to FBT and all 
other high voltage parts is more than 10mm.
Purse Lock  Ø5
>10mm
Conn. Assy 5P
CN801( A PWB)
FBT
DY 1 Conn.
Heatsink
Purse Lock Ø5
Conn. Assy 5P
CN801( A PWB)
DY1 (A PWB)
DY
CN703 (C PWB)
CAUTION:
Keep away from any sharp edge parts, heatsink & high temperature parts.
Rotational Coil
Conn
Conn. Assy 7P
CAUTION:
Keep away from any sharp edge parts, heatsink & high tempera
parts.
CAUTION:
The height of the purse lock must be straight with heatsink height to
avoid connector touching with FBT.