Read Sony KV-HP213M83 (serv.man2) Service Manual online
– 8 –
KV-HP213M83
RM-GA002
SECTION 2
WIRE DRESSING
2-1. INSERT DGC CONNECTOR TO CN601 ( A PWB )
2-2. INSERT AC CORD,SPEAKER WIRE(R), DGC CONN. LEAD ASSY EARTH WITH PURSE LOCK
2-3. DRESS AC POWER CORD, DGC CONN. & LEAD ASSY, EARTH WITH STANDING PURSE LOCK
CAUTION:
Make sure the connector is fully inserted by push & pull (1x).
Make sure the connector is fully inserted by push & pull (1x).
CAUTION:
Dress wires away from beznets front terminal --> prevent wires from
being sandwiched when docking chassis.
Dress wires away from beznets front terminal --> prevent wires from
being sandwiched when docking chassis.
1) Insert DGC connector to CN601.
DGC Connector
1. Dress AC Cord, Speaker wire (R ) ( Red + Black), DGC Conn. &
Lead Assy Earth with purse lock PA (1x) as shown.
Purse Lock PA
AC Cord Power
Speaker wire
(Red+Blk)
DGC Conn.
Lead Assy Earth
Beznet Terminal (Front)
RY600
CN601( A PWB)
Speaker Wire
CN200 (APWB)
DGC Conn.
Lead Assy
Earth
AC Cord Power
CN602 ( A PWB)
Speaker Terminal
(Merah+hitam)
Purse Lock PA
1. Dress AC power cord, DGC conn. & Lead Assy, Earth with
Standing purse lock.
2. Dress Conn Assy, 3P & Lead Assy, Speaker is above of AC power
cord & DGC conn. & at left side Standing Purse lock.
Standing purse lock
Conn Assy,
3P
Lead Assy,
Speaker
Ensure Connectoar Assy, 3P & Lead Assy, Speaker
is
is
ABOVE of AC power cord & DGC connector &
LEFT side of Standing Purse Lock
CN601( A PWB)
DGC Conn.
Lead Assy
Earth
AC Cord Power
CN602 ( A PWB)
Purse Lock PA
CAUTION:
1. Do not overpull the wires during dressing
--> avoid disconnection of wires.
2. Make sure wires are keep away from
sharp edges, heat sinks & other
hight-temperature part.
1. Do not overpull the wires during dressing
--> avoid disconnection of wires.
2. Make sure wires are keep away from
sharp edges, heat sinks & other
hight-temperature part.
Hook
Legend:
Click on the first or last page to see other KV-HP213M83 (serv.man2) service manuals if exist.