SAL70200G2 - Sony Digital Camera Service Manual (repair manual). Page 26

Read Sony SAL70200G2 Service Manual online

2-23
SAL70200G2 (2.8/70-200 G SSM Ⅱ) (70-200mm F2.8 G SSM II)
HELP44
Selection of 4th guide roller (4th lens barrel)
1.  Install the 4th guide roller of which diameter is smaller by 1-size than the dimension described on the outer tube and confirm that the 
4th lens barrel moves smoothly (operation feeling) without play.
4th Guide 
Roller
Outer Tube
4th cam groove
4th Guide 
Roller
4th Lens Block 
Guide Pin
4th Lens Block 
Guide Pin
Location of description 
of 4th cam groove 
dimension
 
In case of  OK :  The selection is finished.
 
In case of  NG :  Proceed to step 2.
2.  Re-assemble the 4th lens barrel at the position where it is rotated 180º with respect to the outer tube in the arrow direction and confirm 
the operation feeling.
4th Guide 
Roller 
4th Guide 
Roller
4th Lens Block 
Guide Pin
4th Lens Block 
Guide Pin
Outer Tube
4th Lens Barrel
 
In case of  OK :  The selection is finished.
 
In case of  NG :  If the operation feeling is better than in step 1, proceed to step 3.
 
In case of  NG :   If the operation feeling is worse than in step 1, turn back the 4th lens barrel 180º with respect to the outer tube and 
proceed to step 3.
3.  Select the 4th guide roller of which diameter is smaller than the described dimension by 2 size.
HELP45
Adhesive bond (B-40): J-6082-614-A
Adhesive bond (LOCTITE 460)
Note:
    Use the adhesive bond (LOCTITE 460) or the equivalent
 
Do not use the instant glue that becomes white when dried.
Grease (G-85): J-6082-626-A
1.  Install the rear light shield barrel to the mount and tighten it with three screws to which tips two drops of adhesive bond (B-40) are 
applied.
Apply the adhesive 
bond (B-40)
Mount
Rear Light 
Shield Barrel
2.  Apply two drops of adhesive bond (LOCTITE 460) to the tip of stopper screw and tighten the stopper screw.
3.  Apply the grease (G-85) to the indicated portion of mount.
4.  Install the lens mount block to the outside barrel, apply two drops of adhesive bond (LOCTITE 460) to the tips of four screws and 
tighten the screws.
Note:
  Fix the flexible BL PWB and lead wires to the grooves of outside barrel at two locations, threading through the outer diameter. And fix them 
with two polyester tapes (black) 10mm.
Apply the adhesive 
bond (B-40)
Apply the adhesive 
bond (B-40)
Apply the adhesive 
bond (LOCTITE 460)
Apply the 
grease (G-85)
Back side of mounting 
claw 3 locations
Stopper Screw
Outside Barrel
Polyester Tape 
(Black) 10mm 
(10X50mm)
Polyester Tape 
(Black) 10mm
(10X50mm)
Lead wires
Flexible BL 
PWB 
Groove
Page of 103
Display

Click on the first or last page to see other SAL70200G2 service manuals if exist.