DSC-W510_ADJ
5-5
Adjustment order
Screen display
5-3-3. WB/AGC Adjustment
The WB/AGC (White Balance/Analog Gain Control) Adjustment order 
is as follows.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
Fig. 5-3-7
The adjustment is complete.
The adjustment is finished abnormally.
Fig. 5-3-8
Malfunction  of  WB/AGC  
adjustment result
5-3-4. MeShut80 Adjustment
The MeShut80 (Mechanical Shutter 80) Adjustment order is as follows.
Note:
Perform the MeShut80 Adjustment after those performed in 5-3-2 to 5-3-3.
Small pattern box (PTB-1450) setting: 
Color temperature = 3100 ± 200K
Luminance: LV12.2 ± 0.5
The adjustment is finished normally.
Fig. 5-3-10
The adjustment is complete.
The adjustment is finished abnormally.
Fig. 5-3-11
Malfunction  of  MeShut80 
adjustment result
Adjustment order
Screen display
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Confirm the indication
on the screen.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-3-8)
In this case, confirm the adjusting environment
and readjust.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “WB/AGC (LV10)”,
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally,
the adjustment completion indication appears
on the screen. (Fig. 5-3-7)
Press the “
(Playback)” button to return to
adjustment menu.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item to “WB/AGC (LV10)”,
and press the “
(Playback)” button. Press the Control button “ v ” “ V ” to change selected item
to “Light Src”, and press the Control button “ b ” “ B ” to set the value as “00002”, and press the
Control button “ z ”.
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-3-6)
Finished normally.
Finished abnormally.
Confirm the indication
on the screen.
Finished abnormally.
Finished normally.
In case of the adjustment is finished abnormally,
the following indication appears on the screen.
(Fig. 5-3-11)
In this case, confirm the adjusting environment
and readjust.
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item. Choose “MeShut80 (LV14)”,
press the Control button “ z ”, select “OK”, and press the Control button “ z ” to start.
* If the adjustment is disabled, refer to “5-1-6. Enabling the Adjustment” to enable the adjustment. (Page 5-3)
In case of the adjustment is finished normally,
the adjustment completion indication appears
on the screen. (Fig. 5-3-10)
Press the “
(Playback)” button to return to
adjustment menu.
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Small pattern box (PTB-1450). (Fig. 5-3-9)
Press the Control button “ b ” “ B ” and “ v ” “ V ” to change selected item to “WB/AGC (LV10)”,
and press the “
(Playback)” button, then confirm that the value of “Light Src” is set as “00002”.
Equipment required: Small pattern box (PTB-1450)
Clear chart
Small pattern box
(PTB-1450)
5 mm
or less
Camera
Fig. 5-3-6
Equipment required: Small pattern box (PTB-1450)
Clear chart
Fig. 5-3-9
Small pattern box
(PTB-1450)
5 mm
or less
Camera