MX-PE10 FIERY (serv.man5). How to Create and_Manage Calibration on a Fiery Driven Printer Using an EFI ES 2000 Spectrophotometer v1 - Sharp Copying Equipment FAQ (repair manual). Page 4

Read Sharp MX-PE10 FIERY (serv.man5) FAQ online

Print Notepads 
EFI Educational Services 
 
4
 
 
 
 
Create a Calibration Set 
1. Select 
Manage in the Calibration section. 
2. Select 
Create New… to create the new Calibration Set. 
3.  Begin by selecting an existing Calibration Set that is similar to the media you will be calibrating 
and OK
4.  When prompted, name the new Calibration set. 
5. Complete 
the 
Recommended Paper text box with the media that will be used to calibrate. This 
can be left blank but it will make managing paper and media easier in the future. 
6.  To assign media properties such as paper size, Paper Weight and Coating required to print using 
the desired media, select
 
Properties to open Job Properties. 
a.  Select the Media tab and assign the appropriate Media TypeMedia WeightCoating
and Paper tray or Paper Catalog for your workflow. 
b. Select 
the 
Image tab and
 
assign the Line/Dot type associated with this calibration set.  
Each Line/Dot type will need to have a unique calibration set and output profile. Note: 
these options will vary with device. 
 
Note: 
Some print engines will require the media to be selected using the Paper Catalog. 
7.  OK to close the Job Properties window and select Continue
8. Select 
the 
Paper Source that will be used to print the Calibration page. 
9.  Set the Measurement method to EFI ES-2000 or the measurement device you have connected 
and select Continue
10.  The Calibration page will print using the Calibration Preferences and Job Properties. Retrieve 
the printed page. 
Page of 7