Job Based Calibration 
1. The 
Job Status area of Command WorkStation will indicate if the calibration time limit has 
expired for the media assigned to the job. If you attempt to print a job with an expired calibration 
the job will be suspended in the Print queue, highlighted in red. 
2.  To calibrate the media used within a job, select a job in the Held queue, right-click and select 
Calibrate Job… 
3. In 
the 
Calibrator window, select the media to calibrate from the Calibrate for: menu. 
4.  Select the paper tray loaded with the required media, select the measurement device and 
Continue
5.  After the calibration page prints, select OK
6.  Follow the on-screen instructions to calibrate the ES-2000 and measure the patch page. 
a.  Place the ES-2000 into its cradle, and calibrate it by pressing the button on its side or 
selecting Continue
b.  Place the calibration page into the backer tray. You will measure all four color strips on 
the calibration page. 
7.  When you have successfully measured the four color strips, select Continue to view the 
calibration results. 
8.  You can choose Test Print to print a comparison page. 
9.  To complete the calibration select Apply & Close. To immediately print the job after the 
calibration is applied, check Print {jobname] before selecting Apply & Close
10.   To view a graph comparing the D-Max measurement values to the target curves, select View 
Measurements
 
Note: 
Review each color in the chart and compare the Measured vs. Target D-Max for 
each color
.
 
If the Visual difference is more than 5% the printer may require servicing. 
11.  After you have compared the D-Max values, select Apply & Close
The new calibration will be used with the all jobs using the same media until the calibration 
expires again. 
 