MX-PE10 FIERY (serv.man5). How to Create and_Manage Calibration on a Fiery Driven Printer Using an EFI ES 2000 Spectrophotometer v1 - Sharp Copying Equipment FAQ (repair manual). Page 5

Read Sharp MX-PE10 FIERY (serv.man5) FAQ online

Print Notepads 
EFI Educational Services 
 
5
 
 
 
Note: 
The page printed was defined in the calibration Preferences. 
The number of calibration pages printed is defined in Calibration Preferences. 
 
 
11.  Follow the on-screen instructions to calibrate the ES-2000 and measure the patch page. 
a.  Place the ES-2000 into its cradle, and calibrate it by pressing the button on its side or 
clicking Continue
b.  Place the calibration page into the backer tray. You will measure all four color strips on 
the calibration page. 
c.  When prompted to read the Cyan strip, place the EFI-ES2000 in the white space above 
the Cyan Strip next to the arrow. Continue to follow the on-screen wizard as it guides you 
through the process to measure each color strip. 
12.  When you have successfully measured the four color strips, select Continue to view the 
calibration results. 
13.  To view a graph comparing the D-Max measurement values to the target curves, select View 
MeasurementsClose the Measurements window when done. 
 
Note: 
Review each color in the chart and compare the Measured vs. Target D-Max for 
each color
.
 
If the Visual difference is more than 5% the printer may require servicing. 
14.  After you have compared the D-Max values, select the output profile that will be associated with 
the new Calibration Set. 
15.  When the output profile is selected, the associated calibration will be applied. 
16.  OK when done and Close Calibrator. 
17.  To learn more about creating custom output profiles, review the How-To Guide: Achieve 
Accurate and Consistent Color with Printer Profiles
Page of 7