Fiery Server Setup of Calibrator Preferences
1. Select
Device Center in Fiery Command WorkStation or choose Tools from the Go menu.
2. In
the
Calibrate section, select Preferences.
3. Set the Measurement method to EFI ES-2000 [ES-1000 compatible], or the device that you will
use to measure the calibration pages.
4. Choose
the
Patch Layout: For this example, select 21 Sorted Patches.
5. Next set the Calibration Status.
a. Check to enable the option Set time limit and display status in Job Center. This
enforces the length of time that can elapse between calibrations. It will also display the
date and time for the last calibration for each of the media stocks used a job.
date and time for the last calibration for each of the media stocks used a job.
b. Set the number of days or hours that can elapse between calibrations.
c. Check to enable Suspend printing when calibration expires if your workflow will
benefit from this setting. By default this setting is not enabled.
Note:
The additional Preference options under the heading: Profiling Method and Patch
Layout are settings for the Color Profiler Suite software and will only be available
when Fiery Color Profiler Suite software is installed on the Command WorkStation
client.
Layout are settings for the Color Profiler Suite software and will only be available
when Fiery Color Profiler Suite software is installed on the Command WorkStation
client.
6. Save the Calibrator Preferences.