MX-PE10 FIERY (serv.man5). How to Create and_Manage Calibration on a Fiery Driven Printer Using an EFI ES 2000 Spectrophotometer v1 - Sharp Copying Equipment FAQ (repair manual). Page 3

Read Sharp MX-PE10 FIERY (serv.man5) FAQ online

Print Notepads 
EFI Educational Services 
 
3
 
 
 
 
Fiery Server Setup of Calibrator Preferences 
1. Select 
Device Center in Fiery Command WorkStation or choose Tools from the Go menu. 
2. In 
the 
Calibrate section, select Preferences
3.  Set the Measurement method to EFI ES-2000 [ES-1000 compatible], or the device that you will 
use to measure the calibration pages. 
4. Choose 
the 
Patch Layout: For this example, select 21 Sorted Patches
5.  Next set the Calibration Status
a.  Check to enable the option Set time limit and display status in Job Center. This 
enforces the length of time that can elapse between calibrations. It will also display the 
date and time for the last calibration for each of the media stocks used a job. 
b.  Set the number of days or hours that can elapse between calibrations. 
c.  Check to enable Suspend printing when calibration expires if your workflow will 
benefit from this setting. By default this setting is not enabled. 
 
Note: 
The additional Preference options under the heading: Profiling Method and Patch 
Layout 
are settings for the Color Profiler Suite software and will only be available 
when Fiery Color Profiler Suite software is installed on the Command WorkStation 
client. 
6.  Save the Calibrator Preferences. 