MX-M356NV SIMULATION 6 – 40
* WARMUP END TIME LL: 1 count = 1s change
Other correction values: 1 count = 1 degree C change
* Items C/D: Correction of "-5" is made for item C and Item D in the case of B5 size
Code descriptions
* Correction value: (-49 - +49), Input value: Actual input value (1 - 99)
43-22
Purpose
Function (Purpose) Used to perform the low-temperature, low-
Function (Purpose) Used to perform the low-temperature, low-
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-04).
the fusing temperature setting of each
paper (SIM43-04).
Section
Operation/Procedure
1) Select an item to be set with the scroll key.
2) Enter the set value with 10-key.
3) Press [OK] key. (The set value is saved.)
1) Select an item to be set with the scroll key.
2) Enter the set value with 10-key.
3) Press [OK] key. (The set value is saved.)
* PLAIN BW DUP APP CNT LL: 1 count = 1s change
Other correction values: 1 count = 1 degree C change
Code descriptions
* Setting value: Target value (-49 - +49), Input value: (Actual input value) 1 - 99
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
Correction value
-49
-25
-5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item
Display
Content
Setting
range
Default
value
A
HL_UM PLAIN BW DUP LL
Correction value for the upper TH_UM black and white plain paper duplex under the LL
environment
environment
1 - 99
55
B
HL_US PLAIN BW DUP LL
Correction value for the upper TH_US black and white plain paper duplex under the LL
environment
environment
1 - 99
55
C
PLAIN BW DUP APP CNT LL
Correction value for applying number of sheets in black and white plain paper duplex under LL
environment
environment
1 - 99
50
D
HL_UM HEAVY BW DUP LL
Correction value for the upper TH_UM set value of black and white heavy paper duplex under the
LL environment
LL environment
1 - 99
55
E
HL_US HEAVY BW DUP LL
Correction value for the upper TH_US set value of black and white heavy paper duplex under the
LL environment
LL environment
1 - 99
55
F
HEAVY BW DUP APP CNT LL
Correction value for applying number of sheets in black and white heavy paper duplex under LL
environment
environment
1 - 99
50
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
Setting value
-49
-25
-5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99