MX-M356NV  SIMULATION  6 – 39
 
43-10
Purpose
Setting
Function (Purpose) Used to set the postcard feed cycle
Section
Operation/Procedure
1) Enter the set value with 10-key.
2) Press [OK] key. (The set value is saved.)
 
43-20
Purpose
Function (Purpose) 
Used to perform the low-temperature, low-
humidity  (L/L)  environment  correction  for
the  fusing  temperature  setting  of  each
paper (SIM43-01).
Section
Operation/Procedure
1) Select an item to be set with the scroll key.
2) Enter the set value with 10-key.
3) Press [OK] key. (The set value is saved.)
Item
Display
Content
Setting 
range
Default 
value
A
POSTCARD CYCLE
Postcard feed cycle
1 - 99
50
Item
Display
Content
Setting 
range
Default 
value
A
HL_UM READY LL
Correction value for TH_UM set value in ready standby under LL environment
1 - 99
55
B
HL_US READY LL
Correction value for TH_US set value in ready standby under LL environment
1 - 99
55
C
HL_UM PLAIN BW LL
Correction value for black and white plain paper TH_UM set value under LL environment
1 - 99
55
D
HL_US PLAIN BW LL
Correction value for black and white plain paper TH_US set value under LL environment
1 - 99
55
E
WARMUP FUMON HL_US T 
LL
Correction value for fusing motor previous rotation start TH_UM set value under LL environment
1 - 99
50
F
WARMUP FUMOFF LL
Fusing motor prior rotation completion time under LL environment
1 - 99
50
G
WARMUP END TIME LL
Correction value for warm-up complete time under LL environment
1 - 99
50
H
HL_UM THIN LL
Correction value for thin paper TH_UM set value under LL environment
1 - 99
55
I
HL_US THIN LL
Correction value for thin paper TH_US set value under LL environment
1 - 99
55
J
HL_UM HEAVY LL
Correction value for heavy paper TH_UM set value under LL environment
1 - 99
55
K
HL_US HEAVY LL
Correction value for heavy paper TH_US set value under LL environment
1 - 99
55
L
HL_UM LABEL LL
Correction value for label paper TH_UM set value under LL environment
1 - 99
55
M
HL_US LABEL LL
Correction value for label paper TH_US set value under LL environment
1 - 99
55
N
HL_UM OHP LL
Correction value for OHP-TH_UM set value under LL environment
1 - 99
55
O
HL_US OHP LL
Correction value for OHP-TH_US set value under LL environment
1 - 99
55
P
HL_UM ENV LL
Correction value for envelope TH_UM set value under LL environment
1 - 99
55
Q
HL_US ENV LL
Correction value for envelope TH_US set value under LL environment
1 - 99
55
R
HL_UM E-STAR LL
Correction value for preheating TH_UM set value under LL environment
1 - 99
55
S
HL_US E-STAR LL
Correction value for preheating TH_US set value under LL environment
1 - 99
55
T
HL_UM PRE-JOB LL
Correction value for the set value of TH_UM when restoring from preheating under LL environment
1 - 99
50
U
HL_UM WARMUP_120L LL
Correction value for TH_UM set value in Warm-Up at 120 degree Cor below under LL environment
1 - 99
55
V
HL_US WARMUP_120L LL
Correction value for TH_US set value in Warm-Up at 120 degree C or below under LL environment
1 - 99
55
W
LO_WARMUP_TIME_LL
Correction value for O, P applying time (timer from Ready complete) under LL environment
1 - 99
50
X
HL_UM WARMUP_120H LL
Correction value for TH_UM set value in Warm-Up at 120 degree C or above under LL environment
1 - 99
55
Y
HL_US WARMUP_120H LL
Correction value for TH_US set value in Warm-Up at 120 degree C or above under LL environment
1 - 99
55
Z
HI_WU_TIME_LL
Correction value for R, S applying time (timer from Ready complete) under LL environment
1 - 99
50
AA
HI_WU_FM_ON_TMP_LL
Correction value for FM prior rotation start TH_UM in Warm-Up at alpha degree C or above under LL 
environment
1 - 99
50
AB
HI_WU_END_TIME_LL
Correction value for Warm-Up completion time in Warm-Up at alpha degree C or above under LL 
environment
1 - 99
50
AC
HI_WU_JOB_SET_TMP_LL
Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha degree C or above 
under LL environment
1 - 99
50
AD
HI_WARMUP_BORDER_LL
Correction value for the threshold value alpha applying SIM43-1-U - W under LL environment
1 - 99
50
AE
LO_WU_JOB_SET_TMP_LL
Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha degree C or below 
under LL environment
1 - 99
50
AF
JOBEND_FUMON_TIME LL 
Correction value for the after rotation time when completing a job under LL environment
1 - 99
50
AG
HI_WU_JOB_SET_TMP 2 
LL
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha degree C or above 
under LL environment
1 - 99
50
AH
LO_WU_JOB_SET_TMP 2 
LL
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha degree C or below 
under LL environment
1 - 99
50