MX-FX10. Service Manual. - Sharp Copying Equipment Service Manual (repair manual). Page 23

Read Sharp MX-FX10 Service Manual online

MX-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 4-13
66
38
Time setting/check
Used to write/read the time (year, month, day, o'clock, minute) into/from the RTC on the FAX PWB.
41
CI signal check
Used to detect the call signal from CI pin and send the call sound to the line and the speaker. The sound 
volume of the call sound follows the soft SW setting. The operations of signal detection and the pseudo ring 
sound send when the signal is detected are continued until the interruption command is made by pressing 
RETURN key.
52
Pseudo ringer check 
• The pseudo ringer sound is delivered both from the machine (speaker).
• This operation is continued until the interruption command is made by pressing RETURN key.
• The LCD displays the TEL/LIU status and the HOOK status.
• While the pseudo ringer is delivered, the RBT )ring back tone) is delivered to the line. The bell is ON for 
1sec and OFF for 2sec. 
Main 
code
Sub 
code
Contents
Remark
Sim66-38 DATE & TIME
Sim66-38 DATE & TIME
Sim66-38 DATE & TIME
Sim66-38 DATE & TIME
Sim66-38 DATE & TIME
DATE
YEAR
XXXX
(2004-2062)
YY
DATE
MONTH
XX
(1-12)
YY
DATE
DAY
XX
(1-31)
YY
TIME
XX:XX
(00-23)
YY
YEAR
20YY
MONTH
YY
DAY
YY
EXEC
After execution, the display shifts
to the sub code input window. 
After inputting 
with numeric 
key, press 
[OK] key.
[OK] key
[OK] key
After inputting 
with numeric 
key, press 
[OK] key.
[OK] key
[OK] key
After inputting 
with numeric 
key.
After inputting 
with numeric 
key.
[OK] key
After inputting 
with numeric 
key.
[OK] key
Sim66-38 DATE & TIME
TIME
XX:XX
(00-59)
YY
xx: The current year/month/day 
      is displayed.
yy: The input value is displayed. 
xx: The current time is displayed.
yy: The input value is displayed.
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input window
Numeric keys
: Item selection and time input
[OK] key
: Settlement
[START] key : Settlement
[BACK] key : Returns to the previous window or
the simulation code input window. 
[C] key
: Input value clear
Sim66-41 CI SIGNAL
[OK] key
Sim66-41 CI SIGNAL
CHECK CI SIGNAL
 EXEC
After pressing 
[OK] key, during 
execution
CI:OFF
PRESS BACK TO STOP
EXEC
When RETUREN key is pressed, 
the window shifts to SIM66-41 
input window.
When detected, 
OFF is changed to ON.
When [BACK] key is pressed 
during detection,the display 
shifts to SIM66-41 input window. 
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input window
[OK] key
: Settlement
[BACK] key
: Returns to the simulation 
code input window.
[BACK] key
[BACK] key
Sim66-52 PSEUDO RNG
Sim66-52 PSEUDO RNG
PSEUDO RINGER CHK
 EXEC
After pressing 
[OK] key, during 
execution
PSEUDO RINGER CHK
PRESS BACK TO STOP
EXEC
SIM66-52 initial window
[CA] key
:Simulation cancel
[INTERRUPT] key :Sub code input window
[OK] key
:Execution
[BACK] key
:Returns to the selection window.
[START] key
:Execution
[C] key
: Disable
[BACK] key
[OK] key
Page of 73
Display

Click on the first or last page to see other MX-FX10 service manuals if exist.