1 Main 
body 
related  We have changed control of the fan in the standby state to reduce the fan sound. 
2 Sim 
related 
This change is applicable only to change of the factory default values, so this 
setting is not changed in firmware version upgrade. If this change is required in the 
field, change the setting via service simulation. 
 
Description 
Before 
change 
After change 
 
Sim44-04 N 
29 
60 
: HV BK_GROUND LIMIT 
Purpose: To cope with a BK highly-concentrated process control error resulting from a 
transfer belt base variation 
 
Description 
Before 
change 
After change 
 
Sim43-01 S 
200 
195 
: HL_UM ENV PAPER 
Sim43-01 T 
140 
150 
: HL_LM ENV PAPER 
Sim43-01 U 
220 
215 
: HL_E ENV PAPER 
Purpose: To increase margin for wrinkle when an envelope is printed 
 
 