MX-C301, MX-C301W (serv.man5). Service Manual (Revised May 2016). - Sharp Copying Equipment Service Manual (repair manual). Page 121

Read Sharp MX-C301 / MX-C301W (serv.man5) Service Manual online

MX-C301  SIMULATION  6 – 4
24
1
Used to clear the jam counter, and the trouble counter. (After completion of maintenance, clear the counters.)
2
Used to clear the number of use (the number of prints) of each paper feed section.
3
Used to clear the finisher, SPF/RSPF, and the scan (reading) unit counter.
4
Used to clear the maintenance counter, the printer counters of the transport unit and the fusing unit. 
(After completion of maintenance, clear the counters.)
5
Used to clear the developer counter. (After replacement of developer, clear the counter.)
6
Used to clear the copy counter.
9
Used clear the printer mode print counter and the self print mode print counter.
10
Used to clear the FAX counter. (Only when FAX is installed)
12
Used to clear the document filing counter.
15
Used to clear the counters related to the scan mode and the image send.
35
Used to clear the usage number of toner cartridge
25
1
Used to check the operations of the developing section.
Process (Developing section)
2
Display the value of the selected sensor and register the toner density control value, toner density control 
voltage, developer adjustment area and sensitivity adjustment value by driving the all drum 
motors.(Automatic adjustment)  
Image process (Photoconductor/
Developing/Transfer/Cleaning)
4
Used to display the operation data of the toner supply quantity. (Not used in the market.)
Process
5
Used to display the toner density correction data. (Not used in the market.)
Process
26
2
Set the paper size of the Tandem LCC
(When the paper size is changed, this simulation must be executed to change the paper size in software.  )
Paper exit
3
Used to set the specifications of the auditor. 
(Setting must be made according to the auditor use conditions.)
Auditor
6
Used to set the specifications (paper, fixed magnification ratio, etc.) of the destination.
7
Used to set the machine ID. 
10
Used to set the trial mode of the network scanner.
18
Used to set Disable/Enable of the toner save mode operation. (For the Japan and the UK versions.)
30
Used to set the operation mode corresponding to the CE mark (Europe safety standards). (For slow start to 
drive the fusing heater lamp)
32
Used to set the specifications of the fusing cleaning operation.
Fusing
35
Used to set the display mode of SIM 22-4 trouble history when a same trouble occurred repeatedly. There are 
two display modes: display as one trouble and display as several series of troubles.
38
Used to set Continue/Stop of print when the maintenance life is reached.
41
Used to set Enable/Disable of the magnification ratio automatic select function (AMS) in the center binding 
mode.
49
Used to set the print speed of postcards mode.
50
Used to set functions.
52
Used to set whether non-printed paper (insertion paper, cover paper) is counted up or not.
53
User auto color calibration (color balance adjustment) Inhibit/Allow setting
69
Used to set the operating conditions for toner near end.
73
Used to set Toner save setting. 
74
Used to set the OSA trial mode.
78
Used to set the password of the remote operation panel.
79
Used to set YES/NO of the pop-up display of user data delete result.
27
1
Used to set non-detection of communication error (U7-00) with RIC. (FSS function)
2
Used to set the sender's registration number and the HOST server telephone number. (FSS function)
4
Used to set the initial call and toner order auto send. (FSS function)
5
Used to set the machine tag No. (This function allows the host computer to check the machine tag No.) (FSS 
function)
Communication (RIC/MODEM)
6
Used to set of the manual service call. (FSS function)
7
Used to set of the enable, alert call out. (FSS function)
9
Used to set the paper transport time recording YES/NO threshold value and shading gain adjustment retry 
number. (FSS function)
10
Used to clear the trouble prediction history information. (FSS function)
11
Used to check the serial communication retry number and the scanner gain adjustment retry number history. 
(FSS function)
12
Used to check the high density, halftone process control and the automatic registration adjustment error 
history. (FSS Function)
14
Used to set the FSS function connection test mode.
15
Used to display the FSS connection status.
16
Used to set the FSS alert send.
17
Used to set the FSS paper order alert.
18
Used to clear the FSS paper feed retry counter.
30
1
Used to check the operations of the sensors and the detectors in other than the paper feed section and the 
control circuits.
2
Used to check the operations of the sensors and the detectors in the paper feed section and the control 
circuits.
43
1
Used to set the fusing reference temperature of each operation mode.
2
Fusing temperature setting.
20
Used to set the environmental correction under low temperature and low humidity (L/L) for the fusing 
temperature setting (SIM 43-1) in each paper mode.
21
Used to set the environment correction under high temperature and high humidity (H/H) for the fusing 
temperature setting (SIM 43-1) in each paper mode.
24
Used to set the correction of the temperature adjustment value of SIM 43-1 and 43-4.
Main
Sub
Functions
Section
Page of 127
Display

Click on the first or last page to see other MX-C301 / MX-C301W (serv.man5) service manuals if exist.