5) Attach the PCL PWB.
● While ensuring that the connector of the PCL PWB is securely con-
nected to that of the copier, attach the PCL PWB to the PWB cover
with seven screws (M3 
× 6) and connect the relay harness connec-
tor.
6) Attach the PCL harness.
● Attach the supplied PCL harness to the PCL PWB, then pass it
through the square hole of the PWB holder, and connect it to the
PCL interface PWB.
Note: Be careful about the direction of the blue lines.
7) Attach the PWB cover.
(1) Fit the upper part of the PWB cover lid to the upper screw
that has been loosened in step 3 above.
(2) While rotating the lower part of the PWB cover lid clock-
wise, fit it to the lower screw.
(3) Tighten the upper and lower screws to secure the cover lid.
8) Attach the PWB cover.
● Attach the supplied PWB cover with five screws (M3 × 6).
9) Attach the PWB cover lid 2.
● Hang the pawls of the supplied PWB cover lid 2 on the PWB cover
and attach the PWB cover lid 2 with two screws (M3 
× 6).
M3X6
M3X6
Blue lines
1
2
1
3
3
M3X6
M3X6
M3X6
M3X6
M3X6
M3X6
Pawls
AR-PB9