AR-M351U, AR-M451U (serv.man17). Simulations - Sharp Copying Equipment Service Manual (repair manual). Page 85

Read Sharp AR-M351U / AR-M451U (serv.man17) Service Manual online

AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 85
Operation/Procedure
To execute this simulation, FAX program writing must be allowed.
(Jumpers and DIP SW depending on the model.) The adjustment
values in PIC are changed or rewritten.
1) Enter the number corresponding to the set item with 10-key.
2) Press [START] key.
3) Enter the set value.
4) Press [P] key.
5) Select 0.
6) The confirmation window is displayed. Select whether the PIC
adjustment values are written or not.
When writing of the PIC adjustment values is normally completed,
“OK” is displayed. In case of an error, “NG” is displayed.
66-43
Purpose
Setting
Function
(Purpose)
PIC adjustment value writing (Only when FAX is 
installed)
Section
FAX
Item
Operation
YES
The adjustment values are collectively written into PIC 
installed in the FAX BOX. 
NO
No writing
Item
Content
Set range Default
0 WRITING for PIC
Writing to PIC
1 ci_level_judge
Number of sensing 
until the CI signal 
level is setteld.
1-15
2
2 ci_cycle_min
CI signal cycle 
min. Time
0-254
10
3 ci_cycle_max
CI signal cycle 
max. time
0-254
107
4 ci_range
CI signal allowable 
range
0-127
5
5 ci_count
CI signal 
settlement number 
of times
1-15
3
6 ci_detect
CID IN- signal 
settlement number 
of times
1-15
8
7 fnet_level_judge
Sense number of 
times until 
settlement of 
FNET signal level
1-15
1
8 fnet_range
FNET signal 
allowable range
0-74
3
9 fnet_time_out
FNET time out 
time
76-255
100
10 fnet_count
FNET signal 
settlement number 
of times
1-15
3
11 poff_time
PON signal OFF 
time
0-15
3
12 mswon_level_judge Sense number of 
times until 
settlement of 
MSW_ON signal 
level
2-15
3
1
SIMULATION 66-43
PIC ADJUSTMENT VALUE WRITING.
ENABLE WRITE PIN(for FAX PROGRAM ROM).
 SELECT 0-12, AND PRESS START.
0.WRITING for PIC  1.ci_level_judge  
2
2.ci_cycle_min 
10
  3.ci_cycle_max 
107
  4.ci_range 
5
 
5.ci_count 
3
  6.ci_detect 
8
  7.fnet_level_judge 
1
8.fnet_range 
3
  9.fnet_time_out 
100
  10.fnet_count 
3
11.poff_time 
3
  12.mswon_level_judge 
3
Press [CUSTOM SETTINGS] key 
or press [START] key.
Select other then 0 , and 
press [START] key.
Select 1.
Select 0 
and press 
[START] key. 
SIMULATION 66-43
PIC ADJUSTMENT VALUE WRITING. INPUT VALUE 1-15, AND 
PRESS START.
1.ci_level_judge(1-15)
1
SIMULATION 66-43
PIC ADJUSTMENT VALUE WRITING.
ARE YOU SURE ?
1.YES
2.NO
SIMULATION 66-43
PIC ADJUSTMENT VALUE WRITING.
EXECUTING...
SIMULATION 66-43
PIC ADJUSTMENT VALUE WRITING.
OK ( or NG )
2
Press [CUSTOM SETTINGS] key
or select 2.
Press [CUSTOM SETTINGS] key.
Page of 88
Display

Click on the first or last page to see other AR-M351U / AR-M451U (serv.man17) service manuals if exist.