AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 79
(Dial pulse make time setting)
1) Enter 1 with 10-key.
2) Press [START] key.
3) Enter the set value with 10-key.
4) Press [START] key.
The dial signal is sent with the set value + 29ms.
When [CUSTOM SETTINGS] key is pressed during execution, the
operation is stopped.
Operation/Procedure
1) Enter 0 with 10-key.
2) Press [START] key. 
The dial signal is outputted.
(Dial pulse make time setting)
1) Enter 1 with 10-key.
2) Press [START] key.
3) Enter the set value with 10-key.
4) Press [START] key.
The dial signal is sent with the set value + 9ms.
When [CUSTOM SETTINGS] key is pressed during execution, the
operation is stopped.
Operation/Procedure
1) Enter 0 with 10-key.
2) Press [START] key. 
The dial signal is outputted.
(Dial pulse make time setting)
1) Enter 1 or 2 with 10-key.
2) Press [START] key.
3) Enter the set value with 10-key.
4) Press [START] key.
When [CUSTOM SETTINGS] key is pressed during execution, the
operation is stopped.
0
EXECUTE
Execute
1
MAKE TIME
Dial pulse make time setting (0 - 15)
66-15
Purpose
Setting/Operation test/Check
Function
(Purpose)
Used to set the make time in the FAX pulse dial 
mode (20pps) and to test the dial signal output. 
(The dial number signal set by SIM 66-13 is 
outputted.) Used to check troubles in dialing and 
to check the operation. (Only when FAX is 
installed)
Section
FAX
Item
Operation
0
EXECUTE
Execute
1
MAKE TIME
Dial pulse make time setting (0 - 15)
SIMULATION 66-14
DIAL TEST(10PPS).  SELECT 0-15, AND PRESS START.
[1. MAKE TIME]
1
7
SIMULATION 66-14
DIAL TEST(10PPS). EXECUTE
1. MAKE TIME  
7
 ; [+29 ms]
SIMULATION 66-14
DIAL TEST(10PPS). SELECT 0-1, AND PRESS START.
0. EXECUTE
1. MAKE TIME  
7
 ; [+29 ms]
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key 
or press [START] key.
Select 1 and 
press [START] key.
Select 0 
and press 
[START] key. 
66-16
Purpose
Setting/Operation test/Check
Function
(Purpose)
Used to check the dial signal (DTMF) output in the 
FAX tone dial mode. (The dial number signal set 
by SIM 66-13 is outputted.) The send level can be 
set to an optional level. Used to check troubles in 
dialing and to check the operation. (Only when 
FAX is installed)
Section
FAX
Item
Operation
Item
Set range
0
EXECUTE
Execution
1
HIGH
High group level
0 - 15dB
2
HIGH LOW
High group - Low group
0 - 15
SIMULATION 66-15
DIAL TEST(20PPS). SELECT 0-1, AND PRESS START.
0. EXECUTE
1. MAKE TIME  
7
 ; [+9 ms]
SIMULATION 66-15
DIAL TEST(20PPS).  SELECT 0-15, AND PRESS START.
[1. MAKE TIME]
1
7
SIMULATION 66-15
DIAL TEST(20PPS).  EXECUTING···.
1. MAKE TIME  
7
 ; [+9 ms]
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key 
or press [START] key.
Select 1 and 
press [START] key.
Select 0 
and press 
[START] key.