AR-C260 (serv.man12). (9) Test Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 8

Read Sharp AR-C260 (serv.man12) Service Manual online

AR-C260/C260M  SIMULATION  9 - 8
41
3
Used to check the operation of 
the document size sensor and 
the related circuit. (The 
document size sensor output 
level can be monitored with the 
LCD display.)
Operation test/check Others
Operation
43
1
Used to set the fusing 
temperature in each operation 
mode.
Setting
Fixing (Fusing)
Operation
44
1
Used to set enable/disable of 
correction operations in the 
image forming (process) 
section.
Setting
Process 
(Photoconductor, 
developing, transfer, 
cleaning)
Operation
2
Black image density sensor 
adjustment
Adjustment
Operation
4
Image forming section 
correction, image density 
sensor adjustment conditions 
setup
Setting
Process 
(Photoconductor, 
development, transfer)
Picture quality
6
Used to forcibly execute the 
image forming section 
correction (high density process 
correction) (process correction).
Operation test/check Process 
(Photoconductor, 
developing, transfer, 
cleaning)
Operation
9
Used to check the data related 
to the image forming section 
correction (the corrected main 
charger grid voltage in each 
print mode, the developing bias 
voltage, etc.). (Used to check 
that correction is performed 
normally or not.)
Adjustment/Setting/
Operation data 
output, check 
(display, print)
Process 
(Photoconductor, 
developing, transfer, 
cleaning)
Data
Operation data 
(Machine 
conditions)
12
Used to check the sampling 
toner image patch density data 
in the image forming section 
correction (high-density 
correction) (process correction). 
This simulation allows to check 
if the correction operation is 
performed normally.)
Adjustment/Setting/
Operation data 
output, check 
(display, print)
Process 
(Photoconductor, 
developing, transfer, 
cleaning)
Data
Operation data 
(Machine 
conditions)
13
Color image density sensor 
adjustment (Adjustment by the 
adjustment jig)
Adjustment
Process (Transfer)
14
Used to monitor the output level 
of the fusing temperature 
sensor, the machine 
temperature sensor, and the 
humidity sensor.
Adjustment/Setting/
Operation data 
output, check 
(display, print)
Others
21
Used to store color balance 
adjustment data. (Half tone 
image correction initial setting) 
(After execution of color 
balance adjustment with SIM 
46-21, this simulation must be 
executed.)
Setting
Picture quality
22
Used to check each color toner 
patch image density UITU in 
half tone image forming section 
correction (process correction). 
(This simulation allows to check 
if correction operation is 
performed normally.)
Adjustment/Setting/
Operation data 
output, check 
(display, print)
Process 
(Photoconductor, 
developing, transfer, 
cleaning)
Data
Operation data 
(Machine 
conditions)
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
Page of 61
Display

Click on the first or last page to see other AR-C260 (serv.man12) service manuals if exist.