AR-C260/C260M  SIMULATION  9 - 13
C. Details
Scanning is performed at the magnification ratio set in procedure 1 is 
executed.
During scanning, the [EXECUTE] key is highlighted. If the [EXECUTE] 
key is pressed under this state, the operation is interrupted.
After completion of scanning, the [EXECUTE] key returns to the normal 
display.
To resume scanning, start with procedure 2. To change the 
magnification ratio, start with procedure 1.
Scanning is performed at the max. scanning length (432 mm). If, 
however, the magnification ratio is set to a value greater than 100% in 
procedure 1, the scanning length is changed accordingly.
The active sensors and detectors are highlighted.
• The light source unit is at the home position. a MHPS is highlighted.
• The light source unit is not at the home position. a MHPS is 
displayed normally.
Scanning is repeatedly performed until the [EXECUTE] key or the 
interruption key is pressed.
Aging of the document feeder is executed under the conditions 
specified with procedure 1. During aging, the [EXECUTE] key is 
highlighted. If the [EXECUTE] key is pressed while it is highlighted, the 
operation is interrupted.
To resume aging, execute with procedure 1. To change the conditions 
for aging, execute with procedure 1.
67
18
Used to clear the Flash data. 
(Printer)
Data clear
Printer
Others
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
1
1
-1
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operations of the scanner unit and its 
control circuit.
Section
Scanner (Image scanning)
Item
Operation
Operation/
Procedure
1. Select the copy (scanning) magnification ratio with 
the zoom key. The magnification ratio can be 
increased or decreased with the [ZOOM] key by the 
increment of 1%. The selected magnification ratio is 
displayed on the magnification ratio display.
2. Press the [EXECUTE] key.
1
-2
Purpose
Operation test/check
Function 
(Purpose)
Used to check the sensors and detectors in the scanner 
section and the related circuits.
Section
Scanner (Image scanning)
Item
Operation
Operation/
Procedure
The operations of sensors and detectors in the scanner 
section are displayed.
1
-5
Purpose
Operation test/check
Function 
(Purpose)
Used to check the scanner (scanning) unit and its 
control circuit.
Section
Scanner (Image scanning)
Item
Operation
Operation/
Procedure
1. Select the copy (scanning) magnification ratio with 
the key (touch panel).  The magnification ratio can be 
increased or decreased with the [ZOOM] key by the 
increment of 1%.
The selected magnification ratio is displayed on the 
magnification ratio display.
2. Select the scan mode (Color / B/W). 
3. Press the [EXECUTE] key.
Scanning is repeated under the conditions set in 
procedures 1 and 2.
During scanning, the [EXECUTE] key is highlighted. 
2
2
-1
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operations of the RADF unit and the 
control circuit. (The document feed operation is 
repeatedly performed.)
Section
RADF
Item
Operation
Operation/
Procedure
1. Select the aging mode with the key. When selection is 
made, the selected item is highlighted.
[1:SIDE]: Single copy aging mode
[2:SIDE]: Duplex copy aging mode
2. Press the [EXECUTE] key.