AR-C170 (serv.man26). Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 19

Read Sharp AR-C170 (serv.man26) Service Manual online

AR-C170M  SIMULATION  9 - 19
2. Select the print mode with [
] key and [
] key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
The [EXECUTE] key is highlighted, the adjustment value entered 
in procedure 2 is set, and the voltage corresponding to the set 
value is outputted.
The voltage is supplied for 30 sec, then the [EXECUTE] key 
returns to the normal display.
If the [EXECUTE] key is pressed while the voltage is supplied, the 
voltage output is stopped and the [EXECUTE] key returns to the 
normal display.
(Set value)
The [EXECUTE] key is highlighted, the adjustment value entered 
in procedure 2 is set, and the voltage corresponding to the set 
value is outputted.
The voltage is supplied for 30 sec, then the [EXECUTE] key 
returns to the normal display.
If the [EXECUTE] key is pressed while the voltage is supplied, the 
voltage output is stopped and the [EXECUTE] key returns to the 
normal display.
In this simulation, when the transfer voltage is supplied, the 
transfer belt and the OPC drum rotates at the same time. 
Therefore, the above parts are not damaged.
8
-2
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of each print 
mode main charger grid voltage and the control 
circuit.
Section
Process 
(Photoconductor, developing, transfer, cleaning)
Operation/
Procedure
(The charging/grid output voltage in each print mode 
can be adjusted and checked.)
1. Select the color mode with the [K], [C], [M], and 
[Y] keys.
When [EXECUTE] key is pressed, the display is 
highlighted and the currently set voltage is 
outputted.
Color
Item Operation 
mode
Adjustment value
Main charger grid voltage
Monitor (High voltage PWB)
Pin 
No.
Actual 
voltage
Adjustment 
range
Specified 
value (Default)
Monitor voltage 
(Specified value)
Connector
K
A: HIGH SPEED
High speed (117mm/s) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
B: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
C: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
C
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
3
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMON
3
–620v
M
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
7
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMON
7
–620v
Y
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
11
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMON
11
–620v
8
-6
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the 
transfer charger current and the control circuit.
Section
Process (Photoconductor, developing, 
transfer, cleaning)
Transfer
Operation/
Procedure
1. Select the color mode with the [K], [C], [M], and 
[Y] keys.
2. Select the copy mode with the scroll key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
Page of 72
Display

Click on the first or last page to see other AR-C170 (serv.man26) service manuals if exist.