AR-C170 (serv.man26). Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 18

Read Sharp AR-C170 (serv.man26) Service Manual online

AR-C170M  SIMULATION  9 - 18
The interval time set range is 1 - 999 sec. [Default: 3]
The setup contents of this simulation remain unchanged until 
the power is turned off. When SIM 7-1 is executed, the setup 
contents are canceled.
Copying is performed with the color selected in procedure 1).
When no print color is selected, the operation is made with the all 
colors.
The [EXECUTE] key is highlighted. When the adjustment value 
entered in procedure 2) and the corresponding voltage is 
outputted.
The voltage is outputted for 30sec, then the [EXECUTE] key 
returns to the normal display. When the EXECUTE key is pressed 
during output of the voltage, the output is stopped and the 
[EXECUTE] key returns to the normal display.
(Set value)
7
-6
Purpose
Setting/Operation test/check
Function 
(Purpose)
Used to set the cycle of intermittent aging.
Item
Operation
Operation/
Procedure
1. Enter the interval aging cycle time (sec) with the 
10-key pad.
2. Press [OK] key (or B/W Start key, Color Start 
key) to set the entered cycle time.
7
-8
Purpose
Setting/Operation test/check
Function 
(Purpose)
Used to set Yes/No of warm-up time display.
Item
Operation
Operation/
Procedure
Press the [EXECUTE] key to set the warm-up time 
display.
When the [EXECUTE] key is pressed, the warm-up 
time display setting is executed and the display 
returns to the simulation main code entry display.
7
-9
Purpose
Setting/Operation test/check
Function 
(Purpose)
Used to check the image quality and operations of 
each color.
Section
Others
Item
Picture quality
Operation/
Procedure
1. Select the color of image quantity and operation 
check with the key.
2. Press the START key.
8
8
-1
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operations of the 
developing bias voltage of each color and the 
control circuit.
Section
Process 
(Photoconductor, developing, transfer, cleaning)
Operation/
Procedure
(
The developing bias output voltage in each of the 
following print modes can be adjusted and checked.)
(Adjustment range)
0 – 585 (Default: See below)
1. Select the color mode with the [K], [C], [M], or [Y] 
key.
2. Select the copy mode with the scroll key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
Color
Item
Operation mode
Adjustment value
Developing bias voltage
Monitor (High voltage PWB)
Pin 
No.
Actual 
voltage
Adjustment 
range
Specified value 
(Default)
Monitor voltage 
(Specified value)
Connector
K
A: HIGH SPEED
High speed (117mm/s) (B & W)
0 – 585
215
3.94 ± 0.1V
CNMONK
3
–215v
B: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
215
3.94 ± 0.1V
CNMONK
3
–215v
C: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
0 – 585
215
3.94 ± 0.1V
CNMONK
3
–215v
C
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
265
5.76 ± 0.1V
CNMON
1
–265v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
0 – 585
265
5.76 ± 0.1V
CNMON
1
–265v
M
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
265
5.76 ± 0.1V
CNMON
5
–265v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
0 – 585
265
5.76 ± 0.1V
CNMON
5
–265v
Y
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
240
4.75 ± 0.1V
CNMON
9
–240v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
0 – 585
240
4.75 ± 0.1V
CNMON
9
–240v
Page of 72
Display

Click on the first or last page to see other AR-C170 (serv.man26) service manuals if exist.